Western Flashback Arrestors-Bodies & CGA Assemblies
Flashback Arrestor Bodies and Assemblies are available for special applications. Flashback Arrestor Bodies consist of ¼ F and ¼ M NPT connections. Assemblies for Adaptors and Pigtails consist of standard CGA connections on both the inlet and outlet sides of a Flashback Arrestor Body. Wester also offers assemblies wiht ball seat check valves for the inlet side of the Flashback Arrestor Body.
Flashback Arrestor Bodies extinguish flashes or flames before they reach the cylinder. Flashback Arrestor Assemblies are designed for installation of acetylene cylinders to prevent flashbacks into the cylinder.
These Flashback Arrestor Bodies/Assemblies can be used in any lead not exceeding ⅜"pipe size which connects an acetylene cylinder to a regulator, manifold or other equipment. Rated flow capacity is 40 SCFH with a 5 PSIG pressure drop. These units are factory assembled and 100% tested for service.
| PART NO. | DESCRIPTION |
|---|
| ARRESTOR BODIES |
|
|
1/4" NPT Female x 1/4" NPT Female |
|
|
with Female Inlet Nut Check Valve |
|
|
1/4" NPT Female x 1/4" NPT Male |
|
|
with Female Inlet Nut Check Valve | UL Listed |
|
| Hover Over Image to Enlarge |
FLASHBACK ARRESTORS-BODIES CGA ADAPTOR ASSEMBLIES
| PART NO. | DESCRIPTION |
|---|
| FLASHBACK ARRESTOR W/ ADAPTOR ASSEMBLIES |
|
|
CGA-300 Commercial Acetylene |
|
|
CGA-300 Commercial Acetylene w/Inlet Check Valve |
|
|
CGA-510 POL Acetylene |
|
|
CGA-510 POL Acetylene w/Inlet Check Valve | |
|
| Hover Over Image to Enlarge |
MANIFOLD PIGTAIL WITH FLASH ARRESTOR
| PART NO. | W/CV | DESCRIPTION | SERVICE |
|---|
|
|
FP-510CV | Horizontal, 24" Length | CGA-510, POL Acetylene |
|
|
FP-510PCV | Horizontal, 18" Length | CGA-510, POL Acetylene | Please Note: Using Flashback Arrestors w/Check Valves as a precaution to avoid potentially dangerous situations is not a substitute for careful handling or strict adherence to safety rules and procedures for handling high pressure gases. Users should not tamper with the internal components of a Flashback Arrestor. Flashback Arrestors cannot be cleaned or refilled after an flash in the system. They must be replaced if the pressure drop through the Arrestor reaches 10 PSIG or more Welders rely on Western's advanced Flashback Arrestors to help prevent serioius incidents caused by reverse gas flows or flashbacks. Western's Flashback Arrestors are designed to stop flashbacks by preventing ignition of mixed gases while protecting equipment such as hoses, regulators, and cylinders.
|
|
| Hover Over Image to Enlarge |
FEATURES
- Color coding for gas service provides added safety - Oxygen (Green), Fuel Gas (Red)
- Internal check valve designed to prevent reverse flow and accidental mixing of oxygen and fuel gases
- Maximum operating pressures are 15 PSIG for Acetylene, 22 PSIG for other fuel gases, and 125 PSIG for Oxygen
- Rated flow capacity of 40 SCFH with a 5 PSIG pressure drop
- Reusable, manual resetting not required
- Torch and Regulator models provide downstream and upstream protection
- 10" maximum cutting capacity
- UL listed and 100% tested
- Complete installation, testing and operating instructions included
- Safe-Mate models feature quick connect design for quick and easy installation and disconnection
| PART NO. | DESCRIPTION |
|---|
| TORCH FLASHBACK ARRESTOR |
|
|
Flashback Arrestor Set, "B" size |
|
|
Flashback Arrestor, Oxygen, "B" size |
|
|
Flashback Arrestor, Fuel Gas, "B" size |
|
|
Flashback Arrestor, Oxygen "A" size |
|
|
Flashback Arrestor, Fuel Gas "A" size |
|
|
Flashback Arrestor, Oxygen, "C" size |
|
|
Flashback Arrestor, Fuel Gas "C" size | |
|
| Hover Over Image to Enlarge |
Regulator Flashback Arrestor
| PART NO. | DESCRIPTION |
|---|
| REGULATOR FLASHBACK ARRESTOR |
|
|
Flashback Arrestor Set "B" size |
|
|
Flashback Arrestor, Oxygen "B" size |
|
|
Flashback Arrestor, Fuel Gas "B" size |
|
|
Flashback Arrestor, Oxygen "A" size |
|
|
Flashback Arrestor, Fuel Gas "A" size | |
|
| Hover Over Image to Enlarge |
This Flashback Arrestor easily mounts on most regulators and has a re-settable pressure control valve which cuts off gas supply in the event of a flashback or reverse gas flow (over 7 PSIG). This helps alert welders/gas users that a flashback and/or reverse gas flow has taken place. Re-setting is easy. Just pull up on the pressure control knob. No disassembly or special tools required.
| PART NO. | DESCRIPTION (9/16-18) |
|---|
|
|
Flashback Arrestor, Oxygen, Regulator Style |
|
|
Flashback Arrestor, Fuel Gas, Regulator Style | |
|
| Hover Over Image to Enlarge |
REGULATOR RE-SETTABLE FLASHBACK ARRESTORS
| PART NO. | DESCRIPTION (9/16-18) |
|---|
|
|
Flashback Arrestor, Oxygen, Regulator Style |
|
|
Flashback Arrestor, Fuel Gas, Regulator Style |
|
| |
|
For more information, call Western Customer Service
at 1-800-783-7890 for technical data sheets
|
|